Design Of Sample And Hold Circuit Using Op-Amp
ABSTRACT
This work is on an overview of sample and hold circuit using op-amp. As the name implies, a sample and hold circuit is a circuit which samples an input signal and holds onto its last sampled value until the input is sampled again. Sample and hold circuits are commonly used in analogue to digital converts, communication circuits, PWM circuits etc. The circuit shown below is of a sample and hold circuit based on uA 741 opamp, n-channel E SAMOSET BS170 and few passive components.
In the circuit MOSFET BS170 (Q1) works as a switch while opamp uA741 is wired as a voltage follower. The signal to be sampled (Vin) is applied to the drain of MOSFET while the sample and hold control voltage (Vs) is applied to the source of the MOSFET.
TABLE OF CONTENTS
COVER PAGE
TITLE PAGE
APPROVAL PAGE
DEDICATION
ACKNOWLEDGEMENT
ABSTRACT
CHAPTER ONE
INTRODUCTION
1.1 AIM OF THE STUDY
- PURPOSE OF THE PROJECT
- APPLICATION OF THE PROJECT
- SIGNIFICANCE OF THE PROJECT
- SCOPE OF THE PROJECT
CHAPTER TWO
LITERATURE REVIEW
- OVERVIEW OF THE PROJECT
- OPERATIONAL AMPLIFIER
- HISTORICAL BACKGROUND OF AN OP-AMP
- THE IC 741 OP-AMP CHARACTERISTICS
- PIN DIAGRAM OF IC 741 OP-AMP
- DESCRIPTION OF BS170 – MOSFET TRANSISTOR
CHAPTER THREE
SYSTEM DESIGN
- BLOCK DIAGRAM SAMPLE AND HOLD CIRCUIT
- SAMPLE AND HOLD OPERATION
- SAMPLE AND HOLD CIRCUIT DIAGRAM
- SAMPLE AND HOLD CIRCUIT WORKING
CHAPTER FOUR
TESTING AND RESULTS
- SYSTEM SETUP PROCEDURES
- COMPONENTS ASSEMBLING PROCEDURE
- TESTING OF SYSTEM OPERATION
- INSTALLATION OF THE COMPLETED DESIGN
CHAPTER FIVE
- CONCLUSION
- REFERENCES
CHAPTER ONE
1.0 INTRODUCTION
In electronics, a sample and hold circuit is an analog device that samples (captures, takes) the voltage of a continuously varying analog signal and holds (locks, freezes) its value at a constant level for a specified minimum period of time. Sample and hold circuits and related peak detectors are the elementary analog memory devices. They are typically used in analog-to-digital converters to eliminate variations in input signal that can corrupt the conversion process.[2]
A typical sample and hold circuit stores electric charge in a capacitor and contains at least one switching device such as a FET (field effect transistor) switch and normally one operational amplifier.[1] To sample the input signal the switch connects the capacitor to the output of a buffer amplifier. The buffer amplifier charges or discharges the capacitor so that the voltage across the capacitor is practically equal, or proportional to, input voltage. In hold mode the switch disconnects the capacitor from the buffer. The capacitor is invariably discharged by its own leakage currents and useful load currents, which makes the circuit inherently volatile, but the loss of voltage (voltage drop) within a specified hold time remains within an acceptable error margin.
1.2 AIM OF THE STUDY
The main objective of this work is to write on a circuit which samples an input signal and holds onto its last sampled value until the input is sampled again. Sample and hold circuits are commonly used in analogue to digital converts, communication circuits, PWM circuits etc. The circuit shown below is of a sample and hold circuit based on uA 741 opamp, n-channel E MOSFET BS170 and few passive components.
1.3 PURPOSE OF THE STUDY
Sample and hold circuits are used in linear systems. In some kinds of analog-to-digital converters, the input is compared to a voltage generated internally from a digital-to-analog converter (DAC). The circuit tries a series of values and stops converting once the voltages are equal, within some defined error margin. If the input value was permitted to change during this comparison process, the resulting conversion would be inaccurate and possibly unrelated to the true input value. Such successive approximation converters will often incorporate internal sample and hold circuitry. In addition, sample and hold circuits are often used when multiple samples need to be measured at the same time. Each value is sampled and held, using a common sample clock.
1.4 APPLICATION OF THE STUDY
The applications of sample and hold circuit include the following
- Sampling Oscilloscopes
- Data Distribution System
- Digital Voltmeters
- Analog Signal Processing
- Signal Constructional Filters
- Data Conversion System
1.5 SIGNIFICANCE OF THE STUDY
The function of the Sample and hold circuit is to sample an analog input signal and hold this value over a certain length of time for subsequent processing. Taking advantages of the excellent properties of MOS capacitors and switches, traditional switched capacitor techniques can be used to realize different S/H circuits.
With the help of sample and hold circuit we can take samples of the analogue signal, followed by a capacitor. It holds these sample for a particular period. As a consequence of this, a constant signal is generated this can be converted into the digital signal with the help of analogue to digital converters.
1.6 SCOPE OF THE STUDY
A typical circuit of the sample and hold stores electric charge in a capacitor and holds at least one switching device like a field effect transistor switch and usually one op-amp (operational amplifier).
To sample the i/p signal the switch unites the capacitor to the o/p of a buffer amplifier. This amplifier amplifies the capacitor so that the voltage across the capacitor is almost equal, or proportional to input voltage. In hold form, the switch separates the capacitor from the buffer. The capacitor is always discharged by its own outflow currents and helpful load currents, which makes the circuit essentially unstable, but the voltage drop in a particular hold time remains within a suitable error margin.
The Title Page should be the first section of your project “Design Of Sample And Hold Circuit Using Op-Amp”, providing essential details like the project title, your name, your supervisor’s name, the institution, and the submission date. After that, the Abstract offers a brief summary of your project, touching on its purpose, methods, results, and conclusions in 150-300 words. The Acknowledgments section is where you can thank those who supported your research, such as your supervisor, peers, or organizations that provided resources.
Next, the Table of Contents organizes the Design Of Sample And Hold Circuit Using Op-Amp by listing its chapters and sections, along with page numbers for easy reference. The List of Figures and List of Tables help guide readers to specific visual elements like graphs, charts, or tables included in the document. There should also be an Abbreviations and Glossary section to explain any specialized terms or acronyms, making the content clearer to readers unfamiliar with the technical language.
The main body of the Design Of Sample And Hold Circuit Using Op-Amp should start with the Introduction, which provides background information, outlines the research problem, states your objectives, and gives a brief overview of your research methods. Following that, the Literature Review offers an in-depth look at previous research relevant to your project, identifying gaps your study aims to address. The Methodology section then explains the research design, tools, and data collection methods you used to conduct the project and analyze the data.
In the Results and Discussion section, you present your findings and discuss them in relation to the Design Of Sample And Hold Circuit Using Op-Amp research questions or objectives, often using tables or charts to help explain the data. The Conclusion summarizes the key results, discusses their implications, and suggests possible directions for future research. You may also include recommendations based on your findings, offering practical advice for improvements or applications. Finally, the Design Of Sample And Hold Circuit Using Op-Amp project should include a References or Bibliography section to list all the sources you cited, as well as Appendices for any additional material. A Statement of Originality is often included to confirm the authenticity of your work