Design And Construction Of A Water Turbidity Tester

Overview

ABSTRACT

Along with the increasing use of water by the community, the quality of water needs to be considered, especially for human consumption Water quality is determined based on the value of turbidity of water. The main aim of this work is to build a turbidity tester. This project develops an Arduino Uno-based water turbidity monitoring system, which is aimed to measure water level and water turbidity levels. The turbidity sensor consists of a photodiode and infrared LED. Measurements of water turbidity using principles of light scattering in the water. The turbidity sensor to detect the intensity of light passing through the scattering of particles and the results of the analog signal voltage. The signal entering Arduino Uno of the ultrasonic sensor and the turbidity sensor will be processed. The measurement results is converted to NTU (Nephelometric Turbidity Units) and liter, then are shown on the LCD display 2×16. This system can potentially help in monitoring water tanks and it is hoped that water quality monitoring system can be applied online.

Cover page

  1. Certification

iii. Dedication

  1. Ackwonledgement
  2. Abstract:

CHAPTER ONE

INTRODUCTION

  • Background of the Study
  • Problem Statement
  • Hypothesis/Research Questions
  • Objective of Study
  • Significance of Study
  • Scope of Study
  • Limitations of Study
  • Definitions of terms

CHAPTER TWO

LITERATURE REVIEW

2.1    Review of Related works

2.2    Contribution to Knowledge

2.3    Proposed system’s Theories

2.4    Expected Results from Hardware &Software

CHAPTER THREE

DESIGN METHODOLOGY

3.1 Material Parts List

3.2Hardware Design Methods

3.3 Software Design Methods

CHAPTER FOUR

RESULTS/ANALYSIS

4.1 Testing of Hardware and software

4.2 Hardware Result/analysis

4.3 Software result/analysis

CHAPTER FIVE

SUMMARY,CONCLUSION AND RECONMENDATIONS

5.1 Summary

5.2 Conclusion

5.3 Recommendation

References

CHAPTER ONE

INTRODUCTION

  • Background of the Study

Turbidity is caused by a huge number of small particles that are suspended in water and invisible to the human eye. While bigger particles are settling down rapidly, small particles – also known as colloids – are settling down very slowly or not at all.

Turbidity in rivers or lakes is often caused by human activities like construction, mining and agriculture. Storm water runoff after a rainfall can wash up sediments from urbanized areas, industries and farmland.

Turbidity is one of the parameters in determining water quality. Turbidity is caused by organic materials and inorganic particles that are suspended in the water [Anderson, 2015]. High water turbidity levels can cause health problems if the water is continually consumed. Water turbidity standards are set between 5-25 NTU (Nephelometric Turbidity Unit) [Ankcorn, 2013].

Water-treatment plant station as a provider of clean water in Indonesia needs to pay attention to water quality that will be distributed to society [Coduto et al, 2010]. Monitoring of water turbidity is required in the water treatment process to ensure water quality, so that water is suitable for use in subsequent processes [Elliot et al, 2019].

The research aim to design a prototype system of monitoring the level of water turbidity. Water turbidity is measured based on the principles of light scattering [Elliot et al, 2019]. Water that has a high turbidity levels will be added chemicals to assist in the deposition of particles in water [Faucette et al, 2015].

Turbidity sensors are designed by using components a photodiode as detector and infrared led as light sources. This system is controlled using Arduino Uno microcontroller. The measurement results of the turbidity sensor in the form of ADC value is converted to units of NTU and is shown on the LCD display 2×16.

  • Problem Statement

Water turbidity is an important factor for maintaining the clearness of water in different places such as ponds and lakes. It is also required for monitoring water sewage treatment systems, washing machines, aquariums and in many more equipment. But there are less instruments that measure turbidity and are quite expensive as well. All this makes it a challenge to measure turbidity. However to overcome this problem, a low cost turbidity tester whose readings are displayed on a LED screen was built.

  • Hypothesis/Research Questions

Hypothesis

H1: There is a significant interface between turbidity sensor and arduino

Research Questions

At the end of this work the student involved shall be able to answer these questions:

  1. What is the operating principle of turbidity tester?
  2. What is the output unit of this turbidity tester?
  • What is the importance of turbidity tester?
    • Objective of Study

Turbidity plays an important role in liquid dynamics and is also used to measure water quality. The main aim of this work is to build a water turbidity tester. The objectives of the work are:

  1. To build a turbidity tester
  2. To measure water water quality
  • To interface LCD, RGB sensor, and turbidity sensor with Arduino Uno microcontroller.
  • Significance of Study

It is very important to measure the turbidity of domestic water supplies, as these supplies often undergo some type of water treatment which can be affected by turbidity. For example, during the rainy season when mud and silt are washed into rivers and streams, high turbidity can quickly block filters and stop them from working effectively. High turbidity will also fill tanks and pipes with mud and silt, and can damage valves and taps. Where chlorination of water is practised, even quite low turbidity will prevent the chlorine killing the germs in the water efficiently.

Measuring the turbidity of the water before and after each part of the system can tell the operator where maintenance or cleaning is needed.

  • Scope of Study

The scope of this work focused on building a water turbidity tester. This system is controlled using Arduino Uno microcontroller. The measurement results of the turbidity sensor in the form of ADC value is converted to units of NTU and is shown on the LCD display 2×16. The turbidity unit is measured in NTU “Nephelometric Turbidity Units” which is global standard. The larger the turbidity is, the cloudy of the sample is. Turbidity sensor connects to the microcontroller through an analog to digital converter through this A to D converter.

  • Limitations of Study

As we all know that no human effort to achieve a set of goals goes without difficulties, certain constraints were noticed in the course of carrying out this project and they are as follows:-

  1. high cost
  2. need power supply (mains or battery)
  • easily damaged
    • Definitions of terms

Turbidity:  is the amount of cloudiness in the water.

Sensor:  is a device that measures physical input from its environment and converts it into data that can be interpreted by either a human or a machine.

Tester: this is an instrument used for testing

 

Research Guidelines

The Title Page should be the first section of your project “Design And Construction Of A Water Turbidity Tester”, providing essential details like the project title, your name, your supervisor’s name, the institution, and the submission date. After that, the Abstract offers a brief summary of your project, touching on its purpose, methods, results, and conclusions in 150-300 words. The Acknowledgments section is where you can thank those who supported your research, such as your supervisor, peers, or organizations that provided resources.

Next, the Table of Contents organizes the Design And Construction Of A Water Turbidity Tester by listing its chapters and sections, along with page numbers for easy reference. The List of Figures and List of Tables help guide readers to specific visual elements like graphs, charts, or tables included in the document. There should also be an Abbreviations and Glossary section to explain any specialized terms or acronyms, making the content clearer to readers unfamiliar with the technical language.

The main body of the Design And Construction Of A Water Turbidity Tester should start with the Introduction, which provides background information, outlines the research problem, states your objectives, and gives a brief overview of your research methods. Following that, the Literature Review offers an in-depth look at previous research relevant to your project, identifying gaps your study aims to address. The Methodology section then explains the research design, tools, and data collection methods you used to conduct the project and analyze the data.

In the Results and Discussion section, you present your findings and discuss them in relation to the Design And Construction Of A Water Turbidity Tester research questions or objectives, often using tables or charts to help explain the data. The Conclusion summarizes the key results, discusses their implications, and suggests possible directions for future research. You may also include recommendations based on your findings, offering practical advice for improvements or applications. Finally, the Design And Construction Of A Water Turbidity Tester project should include a References or Bibliography section to list all the sources you cited, as well as Appendices for any additional material. A Statement of Originality is often included to confirm the authenticity of your work