Transformer is the heart of a sub-station’s equipment, which primarily transforms voltage from one level to the other at the same frequency. The voltage can be raised (Step-up transformer) or lowered (Step-down transformer), but with a fractional decrease or increase in current ratings. Presented in this paper, is the design and implementation of a 2 kVA, 230/400, 600 and 800V, core-type transformer. The materials used were copper wire, silicon steel laminations and is air cooled. A comprehensive design calculation of different parts of the transformer was carefully carried out based on some already established basic transformer design assumptions. E-shaped laminations were 109 and the I-shaped laminations were 93. Pre-commissioning tests such as continuity, short and open circuit test were conducted satisfactory. This reduction in efficiency was as a result of occurrence of losses and heat generated within the transformer. The potential caused of these losses and transformer heating could be attributed to the method of implementation such as the punching of bolt holes and during the cutting of sizes of the metal sheets. The designed transformer finds application in practical classes in undergraduate Electrical Machine Laboratory and domestic use.
1.0 INTRODUCTION
1.1 BACKGROUND OF THE PROJECT
A transformer is a static electromagnetic device that transfers energy by inductive coupling between its winding circuits. In another way, a transformer is an electrical device that transfers electrical energy between two or more circuits through electromagnetic induction. Electromagnetic induction produces an electromotive force within a conductor which is exposed to time varying magnetic fields. A varying current in the primary winding creates a varying magnetic flux in the transformers core and thus a varying magnetic flux through the secondary winding. This varying magnetic flux induces a varying electromotive force (e.m.f) or voltage in the secondary winding. Transformers are used to increase or decrease the alternating voltages in electric power applications. In simple terms, it is an electromagnetic device that steps up or steps down voltages. Making use of Faraday’s Law (discovered in 1831) in conjunction with high magnetic permeability core properties, transformers can be designed to efficiently change AC voltages from one voltage level to another within power networks (Gottlieb, 2012.).
A wide range of transformer designs are used in electronics and electric power applications. Transformers are essential for the transmission, distribution and utilization of electric energy. There are many sizes, shapes and configurations of transformers from tiny to gigantic like those used in power transmission. Some come with stubbed out wires, others with screw or spade terminals, some made for mounting in PC boards, others for being screwed or bolted down.
Transformers are composed of a laminated iron core with one or more windings of wire. They are called transformers because they transform voltage and current from one level to another. An alternating current flowing through one coil of wire, the primary, induces a voltage in one or more other coils of wire, the secondary coils. It is the changing voltage of AC current that induces voltage in the other coils through the changing magnetic field. DC voltage such as from a battery or DC power supply will not work in a transformer.
Only AC makes a transformer work. The magnetic field flows through the iron core. The faster the voltage changes, the higher the frequency (Edward, 2011). However, the output of transformers various from single to double or multiple.
1.2 PROBLEM STATEMENT
There has been the need of transmitting power over long distances with higher efficiency and low maintenance. Step-up transformers are what allow electricity to be transmitted over long distances at low prices. By increasing the voltage of the current that has to be transmitted, the resistance on the line is reduced. This ensures that there are fewer losses along the way. If this were not the case, the power loss on the transmission lines would be so large that it would almost make it impossible for electricity to reach all the places that it does so efficiently today. Also they also don’t need much maintenance. The only maintenance required includes checking the oil, cleaning the contacts, repairing any parts that have been damaged or corroded etc. All of these don’t require much time or money.
1.3 THE AIM AND OBJECTIVES OF THE PROJECT
The aim of this study is to design and construct 2KVA step up with multiple taps. The objectives are as follows:
- To design a step up voltage device
- To study the working and construction a step up transformer
- To increase the efficiency of power supply.
- To have different voltage output in a simple transformer.
1.4 SCOPE AND LIMITATION OF PROJECT
The scope of this project is focused on the construction of step up transformer with input voltage of 230v and output voltage of 400, 600 and 800v. Therefore, the Transformers are used only for stepping up AC voltages or the Alternating Currents. They do not work on the DC or the Direct Current. The limitation are only for the applications related to the AC operations.
As the Step Up Transformer continuously performs its task without any break, it needs a cooling system. Since the Step Up Transformer cannot be shut down to cool, there has to be a provision to attach a round the clock cooling system to the Transformers.
As the voltage capacity increases bigger the transformer size which will also include a bigger cooling system. This creates a bulky and huge Transformer occupying a larger space.
1.5 RELEVANCE OF THE WORK
The relevance of designing the step-up transformer cannot be overemphasized. This is because most electrical or electronic machines and equipment usually comes in various voltages which is solely done by the manufacturer. Also, the voltages as applied to countries are also different. Hence, the step up transformer could be utilized here in Nigeria for transmitting power to a long distance.
1.6 APPLICATIONS OF STEP UP TRANSFORMERS
Applications of Step Up Transformers include:
- Step Up transformers are found in the electronic devices such as Inverters and Stabilizers where in the Transformers help in stabilizing the low voltage to the higher voltage.
- It is also used in the Electrical Distribution of Power
1.7 DEFINITIONS OF TERMS
TRANSFORMER: A transformer is a magnetically coupled coil, a transformer rescues input current and send output voltage, be it step – up or step – down transformer it used in transmission of an electric power.
STANDARD WIRE GAUGE: These are specific number of a wine (coil) it is used in this project to gauge on 17 which has a diagram of 1.422m.
TRANSFORMER: It is a cutout shape rubber material with a hollow in the center and with grove around is to avoid electric link between the core and the coil.
VOLTMETER: This is the instrument used to measure the voltage across the circuit. It is connected in parallel to the winding.
INSULATOR: These are the material used to isolate two conductors from touching each other.
CASING: The outer cover of the transformer this serve is from external hazard was made of metal as earlier stated in our previous chapter.
THE SWITCH: This is a mechanical advice used to open and close a complete electric circuit. The multipurpose low voltage (AC) transformers are connected via switch to the power supply. The primary winding is connected to the power source and the other winding are secondary winding We have step – up transformer and step – down transformer. But in this context emphasis will be lay on the step – up auto transformer.
1.8 PROJECT ORGANIZATION
The entire project is arranged in sections to allow proper report presentation and understanding. The first chapter: the introduction; defines some important concepts on the project and gives a brief description of the problems in the society which results in the need for underground cable fault detector, this also contains the objectives, scope and limitations of the project. The second chapter is the review of related literature which describes briefly the history and classification of developed fault location method. Chapter Three highlight design methodology. Chapter Four highlight on the implementation and testing. Chapter Five is all about the conclusions and recommendations.
COVER PAGE
TITLE PAGE
APPROVAL PAGE
DEDICATION
ACKNOWLEDGEMENT
ABSTRACT
CHAPTER ONE
1.0 INTRODUCTION
1.1 BACKGROUND OF THE PROJECT
1.2 PROBLEM STATEMENT
1.3 AIM AND OBJECTIVE OF THE PROJECT
1.4 SCOPE AND LIMITATION OF THE PROJECT
1.5 RELEVANCE OF THE WORK
1.6 APPLICATION OF THE PROJECT
1.7 DEFINITION OF TERMS
1.8 PROJECT ORGANISATION
CHAPTER TWO
2.0 LITERATURE REVIEW
2.1 REVIEW OF THE STUDY
2.2 HISTORICAL BACKGROUND OF THE PROJECT
2.3 CLASSIFICATION PARAMETERS OF TRANSFORMER
2.4 REVIEW OF DIFFERENT TYPES OF TRANSFORMER
2.5 OTHER TYPES OF TRANSFORMERS
CHAPTER THREE
3.0 SYSTEM DESIGN METHODLOGY
3.1 CIRCUIT DIAGRAM OF A STEP DOWN TRANSFORMER
3.2 BASIC WORKING PRINCIPLE OF A TRANSFORMER
3.3 TRANSFORMER CONSTRUCTION
3.4 CIRCUIT DISCRIPTION OF A STEP-DOWN TRANSFORMER
3.5 M.F EQUATION OF A TRANSFORMER
3.6 DESIGN CALCULATION
CHAPTER FOUR
4.0 TESTING, MEASUREMENT AND RESULTS TESTING OF TRANSFORMER OPERATION
4.1 SHORT-CIRCUIT TEST
4.2 FAULT WITHSTAND
4.3 TRANSFORMER COOLING METHODS
4.4 HOW TO CHECK A STEP DOWN TRANSFORMER
CHAPTER FIVE
5.1 CONCLUSION
5.2 RECOMMENDATION
REFERENCE
The Title Page should be the first section of your project “Construction Of Step-Up Transformer With Multi Output”, providing essential details like the project title, your name, your supervisor’s name, the institution, and the submission date. After that, the Abstract offers a brief summary of your project, touching on its purpose, methods, results, and conclusions in 150-300 words. The Acknowledgments section is where you can thank those who supported your research, such as your supervisor, peers, or organizations that provided resources.
Next, the Table of Contents organizes the Construction Of Step-Up Transformer With Multi Output by listing its chapters and sections, along with page numbers for easy reference. The List of Figures and List of Tables help guide readers to specific visual elements like graphs, charts, or tables included in the document. There should also be an Abbreviations and Glossary section to explain any specialized terms or acronyms, making the content clearer to readers unfamiliar with the technical language.
The main body of the Construction Of Step-Up Transformer With Multi Output should start with the Introduction, which provides background information, outlines the research problem, states your objectives, and gives a brief overview of your research methods. Following that, the Literature Review offers an in-depth look at previous research relevant to your project, identifying gaps your study aims to address. The Methodology section then explains the research design, tools, and data collection methods you used to conduct the project and analyze the data.
In the Results and Discussion section, you present your findings and discuss them in relation to the Construction Of Step-Up Transformer With Multi Output research questions or objectives, often using tables or charts to help explain the data. The Conclusion summarizes the key results, discusses their implications, and suggests possible directions for future research. You may also include recommendations based on your findings, offering practical advice for improvements or applications. Finally, the Construction Of Step-Up Transformer With Multi Output project should include a References or Bibliography section to list all the sources you cited, as well as Appendices for any additional material. A Statement of Originality is often included to confirm the authenticity of your work