Design And Simulation Of Fourth Order Active Band Stop Filter
ABSTRACT
This seminar is ondesigned and simulation of an active fourth order active band stop filter. The filter isdesigned such that it has butter worth response. The topologies that will be used to implement the filterare the multiple feedback (MFB). The filter is designed for radio frequency identification (RFID) system reader to reject all signalsoutside the band (10-20) kHz and to amplify the low antenna signal. This is because the identificationnumber signals which are transmitted from the tag of RFID are (12.5 kHz) and (15.65 kHz).So the passband of the filter is taken to be (10-20) kHz. The values of the resistors and capacitors of the filtercircuit are calculated and the circuits are then simulated withtheMULTISIMprogramtoreachthefinalconclusionwhichdescribestheresultofsimulationcomparedtothe simulationofthe transferfunctionofthe filterusingMUTLABprogram.
TABLE OF CONTENTS
Cover page/Title page
Certification page
CHAPTER ONE
- Introduction
- Background of the Study
- Problem Statement
- Aims and Objective
- Significance of the study
- Applications of fourth order active band stop filter
- Advantages of fourth order active band stop filter
CHAPTER TWO
- Literature Review
- Overview of a filter
- Different types of electronic filter
- Overview of a band stop filter
- Types of band stop filters
- Types of band stop filters
- Working Principle Of A Band Stop Filter
- Review Of Related Studies
CHAPTER THREE
- Method
- Fourth order active band stop filter design
- Fourth-orderorder active band filterdesignimplementation
- NImultisimimplementation
- Matlabimplementation
- Resultsandanalysis
- Conclusion
CHAPTER ONE
1.0 INTRODUCTION
1.1 BACKGROUND OF THE STUDY
Radio Frequency Identification (RFID) is an enabling technology for remotelyidentifying,monitoring,and tracking various objects of interest using radio wavetransmissions.Theautomaticidentificationofobjectsispossiblebywirelesscommunications between a tag (attached to an object) and its reader (interrogator) atdistantlocation(Gleich et al., 2015).
A typical RFID system is comprised of the following components (Buzug et al., 2012):
- Areader,orinterrogator,withoneormoreantennasthatareconnectedtoahostcomputerthroughvarious kindsofinterfaces.
Ataghasanidentificationnumber(ID)andareaderrecognizes an objectthroughconsecutivecommunicationswiththetagattachedtoit.Thereadersendsouta signal which supplies power and instructions to a tag. The tag transmits its ID to thereader and the reader consults an external data base with received ID to recognize theobject(Buzug et al., 2012).
An active band-pass filter is used for the RFID system reader to reject all signalsoutside the (10-20) kHz signals and to amplify the low antenna signal. These arebecausetheIDsignalsfromthetagare(12.5kHz)and(15.65kHz)andsignalpowerisverylow (Biederer et al., 2019).
In this paper, RFID system is considered with 125 kHz, FSK modulation scheme. Inlow frequency RFID system, analog active filters are used because of the followingadvantages (Biederer et al., 2019):
- The maximum gain or the maximum value of the transfer function may be greaterthanunity.
- The loading effect is minimal, which means that the output response of the activefilter isessentiallyindependentoftheloaddrivenbythefilter.
- Active filters can be smaller, lighter, and more accurate than passive filters whichcan be large and heavy at low frequencies if inductors arerequired.
- Higherorderfilterscaneasilybecascadedsinceeachop-ampcanbesecondorder.
The simplest design of a band-pass filter is the connection of a high-pass filterandalowpassfilterinseries,whichiscommonlydoneinwide-bandfilterapplications. Thus, a first order high-pass and a first-order low-pass provide a second-order band-pass, while a second-order high-pass and a second-order low-pass result ina fourth-order band-pass response. In comparison to wide-band filters, narrow-bandfilters of higher order consist of cascaded second-order band-pass filters(Biederer et al., 2019).
Themostcommon filterresponsesaretheButterworth, Tschebyscheff,andBessel types. Among these responses, Butterworth type is used to get a maximally-flatresponse. Also, itexhibits a nearly flatpass band with noripple. The roll-off issmooth and monotonic, with a low-pass or high pass roll off 20dB/dec for every pole.Thus,afourth orderButterworth band-pass filter would have an attenuation rate of40dB/decand-40dB/dec (Biederer et al., 2019).
This work is on simulation of 4th order active band stop filter. The design will be carried out in order to meet the design specifications and the simulation will be done using MATLABsimulationresultwillbediscussed.
1.2 PROBLEM STATEMENT
Appliances malfunctions when a frequency is transmitted outside the required frequency band. In order to solve this problem a fourth order active band stop filter is used. The filter is designed for radio frequency identification (RFID) system reader to reject all signalsoutside the band (10-20) kHz and to amplify the low antenna signal.
1.3 AIM AND OBJECTIVE OF THE STUDY
The aim of this seminar is to carry out a study on design and simulation of fourth order active band stop filter. The objectives of the study are:
- To carry out a study on the workings of a fourth order active band stop filter
- Study the operation and application of filters in RFID appliances.
- To carry out a simulation using MATLAB & MULTISIM simulation.
1.4 SIGNIFICANCE OF THE STUDY
This study will serve a means of studying the application of filter in electronics and telecommunication.
1.5 APPLICATIONS OF FOURTH ORDER ACTIVE BAND STOP FILTER
The applications include:
- Fourth order active band stop filter is used in various speaker systems to enable and enhance audio quality.
- They are used in Telecommunications (Telephone, Digital Subscriber Line) to reduce the noise while signal transmission.
- It is reduced to clear static in radio devices.
- They are also used in instrument amplifiers, especially for acoustic instruments like Electronic Guitar in reducing the humming sound produced at 60 Hz.
- In the field of medicine, Electrocardiogram (ECG) machine also has Fourth order active band stop filter for hassle-free operations.
- They are a vital part of signal and image processing
- Optical Filters also have Fourth order active band stop filters for use in laser eye protection applications.
- It filters out unwanted noises from the duplexes and switches.
1.6 ADVANTAGES OF FOURTH ORDER ACTIVE BAND STOP FILTER
The advantages include:
- It offers Low Passband insertion loss and group delay.
- Unwanted Signals are effectively suppressed while Transmission.
- These Filters are preferred while transmitting high-power signals.
The Title Page should be the first section of your project “Design And Simulation Of Fourth Order Active Band Stop Filter”, providing essential details like the project title, your name, your supervisor’s name, the institution, and the submission date. After that, the Abstract offers a brief summary of your project, touching on its purpose, methods, results, and conclusions in 150-300 words. The Acknowledgments section is where you can thank those who supported your research, such as your supervisor, peers, or organizations that provided resources.
Next, the Table of Contents organizes the Design And Simulation Of Fourth Order Active Band Stop Filter by listing its chapters and sections, along with page numbers for easy reference. The List of Figures and List of Tables help guide readers to specific visual elements like graphs, charts, or tables included in the document. There should also be an Abbreviations and Glossary section to explain any specialized terms or acronyms, making the content clearer to readers unfamiliar with the technical language.
The main body of the Design And Simulation Of Fourth Order Active Band Stop Filter should start with the Introduction, which provides background information, outlines the research problem, states your objectives, and gives a brief overview of your research methods. Following that, the Literature Review offers an in-depth look at previous research relevant to your project, identifying gaps your study aims to address. The Methodology section then explains the research design, tools, and data collection methods you used to conduct the project and analyze the data.
In the Results and Discussion section, you present your findings and discuss them in relation to the Design And Simulation Of Fourth Order Active Band Stop Filter research questions or objectives, often using tables or charts to help explain the data. The Conclusion summarizes the key results, discusses their implications, and suggests possible directions for future research. You may also include recommendations based on your findings, offering practical advice for improvements or applications. Finally, the Design And Simulation Of Fourth Order Active Band Stop Filter project should include a References or Bibliography section to list all the sources you cited, as well as Appendices for any additional material. A Statement of Originality is often included to confirm the authenticity of your work