Power Transformer Winding Thermal Analysis Considering Load Condition And Type Of Oil
ABSTRACT
Power transformer outages have a considerable economic impact on the operation of an electrical network. In order to draw maximum power from transformers and, at the same time, avoid thermal mishaps, it is essential to carefully study its thermal behavior. Furthermore, an accurate computation of the hottest spot temperature (HST) helps in a realistic estimation of the reliability and remaining life of the transformer winding insulation. This paper presents steady state temperature distribution of a power transformer layer-type winding using conjugated heat transfer analysis, therefore energy and Navier-Stokes equations are solved using finite difference method. Meanwhile, the effects of load conditions and type of oil are investigated using the model. Oil in the transformer is assumed nearly incompressible and oil parameters such as thermal conductivity, special heat, viscosity, and density vary with temperature. Comparing the results with those obtained from finite integral transform checks the validity and accuracy of the proposed method.
TABLE OF CONTENTS
COVER PAGE
TITLE PAGE
APPROVAL PAGE
DEDICATION
ACKNOWELDGEMENT
ABSTRACT
CHAPTER ONE
1.1 INTRODUCTION
1.2 OBJECTIVE OF THE STUDY
1.3 SCOPE OF THE STUDY
CHAPTER TWO
LITERATURE REVIEW
2.1 REVIEW OF DIFFERENCE BETWEEN POWER TRANSFORMER AND DISTRIBUTION TRANSFORMER
2.2 REVIIEW INSULATING OIL
2.3 TYPES OF TRANSFORMER OIL
2.4 PROPERTIES OF TRANSFORMER INSULATING OIL
2.5 CHEMICAL PARAMETERS OF TRANSFORMER OIL
2.6 PHYSICAL PARAMETERS OF TRANSFORMER OIL
CHAPTER THREE
METHODOLOGY
3.1 POWER TRANSFORMER CONSTRUCTION – WINDINGS
3.2 TRANSFORMER CONSTRUCTION OF THE CORE
3.3 POWER TRANSFORMER CORE CONSTRUCTION
3.4 TRANSFORMER LAMINATIONS
3.5 TRANSFORMER CORE TYPES
3.6 TRANSFORMER WINDING ARRANGEMENTS
3.7 TRANSFORMER CORE LOSSES
CHAPTER FOUR
TEMPERATURE RISE TEST OF TRANSFORMER
4.1 TEMPERATURE RISE TEST FOR TOP OIL OF TRANSFORMER
4.2 WINDING TEMPERATURE RISE TEST ON TRANSFORMER
CHAPTER FIVE
- CONCLUSION
- REFERENCES
CHAPTER ONE
1.1 INTRODUCTION
In a power transformer, a part of the electrical energy is converted into the heat. Although this part is quite small comparing to total electric power transferred through a transformer, it causes significant temperature rise, which represents the limiting criteria for possible power transfer through a transformer. That is why the precise calculation of temperatures in critical points (top oil and the hottest solid insulation spot) is of practical interest. Thermal impact leads not only to long-term oil/paper-insulation degradation; it is also a limiting factor for the transformer operation. Therefore, the knowledge of the temperature, especially the hottest spot temperature, is of high interest. If the temperature rise goes beyond the permissible value, the load of transformer must be reduced or an auxiliary transformer is used in order to preserve the insulation from deterioration. For an oil-immersed transformer, the oil surrounds the transformer body. Oil is a nearly incompressible fluid and density changes due to temperature rise, therefore oil moves in the transformer. The heat transferred by convection is the most important method of heat transfer.
Hottest spot temperature must not exceed the prescribed value in order to avoid insulation faults. A hottest spot temperature calculation is given in the International Standards. The algorithm for calculating the hottest spot temperature of a directly loaded transformer using data obtained in a short circuit heating test. Heat transfer theory results from winding to oil.
In this paper, author has proposed a procedure for obtaining the temperature distribution in the power transformer and the effects of load conditions and type of oil are investigated using the model. For this reason energy and Navier-Stokes equations are solved using finite difference method. The model can be used for temperature calculation on the arbitrary change of current and outside air temperature.
1.2 OBJECTIVE OF THE STUDY
The objective of this paper is to presents steady state temperature distribution of a power transformer layer-type winding using conjugated heat transfer analysis, therefore energy and Navier-Stokes equations are solved using finite difference method. Meanwhile, the effects of load conditions and type of oil on HST are investigated using the model.
1.3 SCOPE OF THE STUDY
Thermal impact leads not only to long-term oil degradation; it is also a limiting factor for the transformer operation.Therefore, the knowledge of the temperature, especially the hottest spot temperature, is of high interest. If the temperature rise goes beyond the permissible value, in order to preserve the insulation from deterioration, the load of transformer must be reduced or an auxiliary transformer is used. For an oil-immersed transformer, the oil surrounds the transformer body. Oil is a nearly incompressible fluid and density changes due to temperature rise, therefore oil moves in the transformer. The heat transferred by convection is the most important method of heat transfer. The analytical solution of convection equation is normally difficult and sometimes it is impossible due to the complexity of the geometry.
The Title Page should be the first section of your project “Power Transformer Winding Thermal Analysis Considering Load Condition And Type Of Oil”, providing essential details like the project title, your name, your supervisor’s name, the institution, and the submission date. After that, the Abstract offers a brief summary of your project, touching on its purpose, methods, results, and conclusions in 150-300 words. The Acknowledgments section is where you can thank those who supported your research, such as your supervisor, peers, or organizations that provided resources.
Next, the Table of Contents organizes the Power Transformer Winding Thermal Analysis Considering Load Condition And Type Of Oil by listing its chapters and sections, along with page numbers for easy reference. The List of Figures and List of Tables help guide readers to specific visual elements like graphs, charts, or tables included in the document. There should also be an Abbreviations and Glossary section to explain any specialized terms or acronyms, making the content clearer to readers unfamiliar with the technical language.
The main body of the Power Transformer Winding Thermal Analysis Considering Load Condition And Type Of Oil should start with the Introduction, which provides background information, outlines the research problem, states your objectives, and gives a brief overview of your research methods. Following that, the Literature Review offers an in-depth look at previous research relevant to your project, identifying gaps your study aims to address. The Methodology section then explains the research design, tools, and data collection methods you used to conduct the project and analyze the data.
In the Results and Discussion section, you present your findings and discuss them in relation to the Power Transformer Winding Thermal Analysis Considering Load Condition And Type Of Oil research questions or objectives, often using tables or charts to help explain the data. The Conclusion summarizes the key results, discusses their implications, and suggests possible directions for future research. You may also include recommendations based on your findings, offering practical advice for improvements or applications. Finally, the Power Transformer Winding Thermal Analysis Considering Load Condition And Type Of Oil project should include a References or Bibliography section to list all the sources you cited, as well as Appendices for any additional material. A Statement of Originality is often included to confirm the authenticity of your work